Olympus ckx31 manual
Binocular tube of CKX31 frame C-5 4. C-7 5. C-9 6. Outline 1 CKX Inverted culture microscope with fixed observation tube successor to CK30 CKX Inverted culture microscope with interchangeable observation tube successor to CK40 Reflected light fluorescence attachment mountable 2 Target market and applications Tissue culture routine market represented by culture, growth, immunity and pharmacy.
Page 5: Using Conditions 4 Observation is possible in F. Dimensions 1 CKX31 2 3 7. CKX31 frame Change the position to adjust absolute optical axis. AB3X14SA, 4pcs.
Refer to D Grease; OT Adhesive; KNOB Standard: 0. Adjustment guide mounting position Working force: standard 0. For adjustment procedure, refer to D Adjusting parfocality See D-5 to D For the composition of lenes, refer to the Fig. Set the jigs to the microscope and check the parfocality. Adjustment procedure: 1 Remove the stage part, and take off the covers.
Preparation for optical adjustment See D Jigs : See D Absolute optical axis For the composition of lenses, refer to the Fig. Adjustment procedure: 1 Remove the stage, and take off the covers. List of adhesives Page Getting Ready 1. A microscope is a precision instrument. Handle it with care and avoid subjecting it to sudden or severe impact. Page 6 Maintenance and Storage 1. Clean all glass components by wiping gently with gauze. Since solvents such as ether and alcohol are highly flammable, they must be handled carefully.
Be sure to keep these chemicals away from open flames or potential sources of electrical sparks -- for example, electrical equipment that is being switched on or off. Remove the band when unpacking the microscope. Be sure to store the band for re-transportation of the microscope. When using the microscope for the first time, remove the transport lock pins before use. Page 10 knob to move the specimen into Make sure that the revolving the light path.
The coarse adjustment knob tension is preadjusted for easy use. However, if desired, one can change the tension using the tension adjustment ring.
Always place the specimen with great care. Do not use the specimen holder or stage to move the specimen, for this will damage the rotating mechanisms of the knobs.
This will prevent the eyeglasses from contacting and scratching the eyepieces. When Not Wearing Eyeglasses Extend the folded eye shades in the direction of the arrow for efficient Fig. With the 10X objective engaged and the specimen brought into focus, turn the field iris diaphragm ring counterclockwise to stop down the diaphragm to near its minimum size. When the oil of other make is used the surface of the Top lens of Condenser may be damaged. Focus on the specimen by switching the objectives fro the lowest power to highest power.
Page Troubleshooting Guide Under certain conditions, performance of the unit may be adversely affected by factors other than defects. If problems occur, please review the following list and take remedial action as needed. If you cannot solve the problem after checking the entire list, please contact your local Olympus representative for assistance.
Tighten it. Illumination Illuminator built in.